Metering Blog

Here we are publishing answers on your questions related to electrical energy and metering. If you have questions, please use our contact form or write a comment below the related article.
Add us on LinkedIn or with WeChat ID: SZ002121 to stay tuned.

blog qr-code
share this page
WeChat QR
scan in WeChat

The calculators and animations in this blog work with JavaScript-enabled Web browsers.
Please make sure your Web browser is JavaScript-enabled.

Since End of 2020 we are using asynchronous scripting technologies. If you can not see the clocks below working, your browser needs to be updated.

Your System Time
88:8888 8888-88-88 888
Shenzhen Time
88:8888 8888-88-88 888

My meter is running too slow

My meter is running too slow

The end-user had an energy meter with rotating disk (electromechanical). These meters are usually already in the field for more than 30 years. ...
Energy Saving with Little Helpers?

Energy Saving with Little Helpers?

I recently stumbled over some advertisements related to plug-in or paste devices which are claimed to reduce the electricity bill by an average of 10%. ...
User Interface Unit Simulator

User Interface Unit Simulator

By now the UIU / CIU short-codes are not unified. We have collected and merged all recent requests. ...
How Mean is the Value?

How Mean is the Value?

CLOU energy meters and test equipment is measuring the true RMS value by waveform sampling. There are other methods, but they are less accurate. ...
Power Grid Stability and Renewable Energy

Power Grid Stability and Renewable Energy

With increasing percentage of renewable energy on power generation we will see more disturbances in the grid. ...
Waveform Sampling for Electrical Measurements

Waveform Sampling for Electrical Measurements

The interactive graphics below shows the impact on sampling rates on different waveforms. The error calculation is based on true-rms for a wave with 360 samples and for training purpose only. ...
The Over- and Under Voltage Disconnection

The Over- and Under Voltage Disconnection

The phase to neutral supply voltage is controlled by the power generation companies and utilities by using transformers with on-load tap changers. Depending on the region you can find different supply voltages. ...
The Over-Current Disconnect Function

The Over-Current Disconnect Function

Electronic meters with build-in relays can serve for various functionalities. By IEC62052-11 Ed.2 the name for this sort of relays is Supply Control Switch (SCS). ...
Who pays for the Beep?

Who pays for the Beep?

Electronic energy meters, especially those with STS payment functions have the ability to give an alarm. Low credit is a typical example. ...
Load Limiting for Energy Meters

Load Limiting for Energy Meters

Electronic energy meters with a build-in load switch can be programmed for a maximum load. If a consumer exceeds the limit, he will be disconnected ...

12 Replies to “Metering Blog”

  1. I have a clou meter token and am just wondering how i can silence the beeping alarm that goes off when your are low on tokens. Its kinda annoying. Ypur help will be highly appreciated.
    Regards,
    Steve

    1. Steve, try code 812 on your UIU (user interface unit) and confirm by pressing the enter-button (blue or red). If it doesn’t work, please tell us the meter model type.

    1. If the energy meter has a function for measuring reactive energy, it must have a test output (a flashing diode) indicating the reactive consumption. This test output has a meter constant, indicated in e.g. pulses per kvarh. You set measurement mode in your test plan to reactive measurement and adjust the scanning heads in front of the reactive diode. All other procedure is the same like active accuracy test. The settings for reactive power is done inside the test bench and reference standard automatically.

  2. which is the standard to be used for testing of for Reactive power in energy meter and what are the acceptable error margins?

    1. The IEC 62053-23 is applicable for static meters for reactive energy (classes 2 and 3). The allowed errors for accuracy are given in the related tables. If you have a meter with reactive class 2, the allowed error is +/-2% for all balanced loads above 0.1 Ib and power-factor 1.

  3. My CLOU (CL710K11) just shows zeros when I try to enquire balance or input new token, I think it is not communicating with the power source

    1. The possible reason could be long communicate distance or the power cable quality,plsase use another socket and try again. if still doesn’t work,pls confirm whether the UIU address is right one( enter 1593570 plus the meter number to set the UIU address).

  4. Where can I find the operational manual for clou meter, with series number CL710K11

    1. Thank you for your message. The operation manual is for the power company or utility. End users get an introduction by the power company and a reference card with the user interface short codes. The configuration for each power company is different. If you are in doubt about a function, ask your power supplier.

    2. My CL710K11 meter
      Red light is lit next to the word “WIRING” and I noticed low power in house today. Any idea what could be the problem.

      1. It indicates a poor communication between the user interface unit and the meter. One reason behind can be a very low supply voltage from the grid.