Here we are publishing answers on your questions related to electrical energy and metering. If you have questions, please use our contact form or write a comment below the related article.
Add us on LinkedIn or with WeChat ID: SZ002121 to stay tuned.

blog qr-code
share this page
WeChat QR
scan in WeChat

The calculators and animations in this blog work with JavaScript-enabled Web browsers.
Please make sure your Web browser is JavaScript-enabled.

Since End of 2020 we are using asynchronous scripting technologies. If you can not see the clocks below working, your browser needs to be updated.

Your System Time
88:8888 8888-88-88 888
Shenzhen Time
88:8888 8888-88-88 888

The Uttar Pradesh Smart Meter Shutdown

The Uttar Pradesh Smart Meter Shutdown

A sudden shutdown of 150,000 smart meters happened recently in the Uttar Pradesh province, India. ...
Electrostatic Discharge Test for Energy Meters

Electrostatic Discharge Test for Energy Meters

Sometimes it happens that you touch the door knob and you get an electrical shock. It's not dramatically for your body but an unpleasant feeling. ...
Don’t touch anything!

Don’t touch anything!

In your utility laboratory and for your on-site workers you take of course care for a proper training on the job and especially for personal safety. ...
The Stability of IEC Standards

The Stability of IEC Standards

Meter manufacturers, utility laboratories and type testing institutes have planning security until year 2025. ...
The Critical Change Value

The Critical Change Value

The critical change value indicates the maximum amount of change allowed in the meter’s energy registers during disturbance tests without any current flowing in the meter’s current circuits. ...
The Optical Test Output and Pulses

The Optical Test Output and Pulses

Each electronic energy meter must have at least one optical test output. Commonly its named with flashing pulse diode or similar. ...
Test Bench Stability of the Output Settings

Test Bench Stability of the Output Settings

In customer requests and tenders you can still find extensive requirements for the stability of the output settings. ...
Where is the Basic Current?

Where is the Basic Current?

In the last 100 years we had a lovely Ib for direct connected meters. Now the name has changed to nominal current In. ...
The Initial Start-Up for Energy Meters

The Initial Start-Up for Energy Meters

Electronic energy meters are like small computers. The need some time for starting up. ...
Influence of Fast Load Current Variations

Influence of Fast Load Current Variations

The load current can vary frequently with high amplitude. The test conditions in the older versions of the IEC62052-11 have all be static... ...

12 Replies to “Metering Blog”

  1. I have a clou meter token and am just wondering how i can silence the beeping alarm that goes off when your are low on tokens. Its kinda annoying. Ypur help will be highly appreciated.
    Regards,
    Steve

    1. Steve, try code 812 on your UIU (user interface unit) and confirm by pressing the enter-button (blue or red). If it doesn’t work, please tell us the meter model type.

    1. If the energy meter has a function for measuring reactive energy, it must have a test output (a flashing diode) indicating the reactive consumption. This test output has a meter constant, indicated in e.g. pulses per kvarh. You set measurement mode in your test plan to reactive measurement and adjust the scanning heads in front of the reactive diode. All other procedure is the same like active accuracy test. The settings for reactive power is done inside the test bench and reference standard automatically.

  2. which is the standard to be used for testing of for Reactive power in energy meter and what are the acceptable error margins?

    1. The IEC 62053-23 is applicable for static meters for reactive energy (classes 2 and 3). The allowed errors for accuracy are given in the related tables. If you have a meter with reactive class 2, the allowed error is +/-2% for all balanced loads above 0.1 Ib and power-factor 1.

  3. My CLOU (CL710K11) just shows zeros when I try to enquire balance or input new token, I think it is not communicating with the power source

    1. The possible reason could be long communicate distance or the power cable quality,plsase use another socket and try again. if still doesn’t work,pls confirm whether the UIU address is right one( enter 1593570 plus the meter number to set the UIU address).

  4. Where can I find the operational manual for clou meter, with series number CL710K11

    1. Thank you for your message. The operation manual is for the power company or utility. End users get an introduction by the power company and a reference card with the user interface short codes. The configuration for each power company is different. If you are in doubt about a function, ask your power supplier.

    2. My CL710K11 meter
      Red light is lit next to the word “WIRING” and I noticed low power in house today. Any idea what could be the problem.

      1. It indicates a poor communication between the user interface unit and the meter. One reason behind can be a very low supply voltage from the grid.