The Last Gasp Outage Notification

The Last Gasp Outage Notification

Smart meters can generate a Push message in case of power fail. This event is called Last Gasp. ...
Practical Use of Load Profiles

Practical Use of Load Profiles

Electronic energy meters can save internally a lot of data. When this data are saved periodically with time stamp, we talk about a load profile. ...
The TOU Tariff Structure

The TOU Tariff Structure

TOU stands for time of use. It's getting popular together with smart energy meters and advanced metering infrastructure (AMI). ...
Energy Meters and Tariffs

Energy Meters and Tariffs

Electronic energy meters are recording the actual power over a certain time. The microprocessor inside of these meters allows all kind of additional calculations. ...
Sealing of Energy Meters

Sealing of Energy Meters

Electrical Energy meters are sealed to detect possible manipulations. The utility field workers check the meter installations regular. ...
Sealing of Optical Ports

Sealing of Optical Ports

The optical port is for local communication with energy meters. With suitable software and an optical reading head you can access to the meter for reading and writing certain parameters. ...
Principle for Accuracy Testing of Energy Meters

Principle for Accuracy Testing of Energy Meters

Now meter testing is much more comfortable. Actually you only need to put the meters on the rack. For testing big quantities of meters a robot can also do the job. But what happens inside? ...
Basics of Energy Meter Accuracy Tests

Basics of Energy Meter Accuracy Tests

In the past without any electronics a accuracy test was really challenging. You needed a voltage/current source with a high stability, calibrated wattmeters and a calibrated stop-watch. ...
How does a scanning head work?

How does a scanning head work?

Each energy meter used for billing must have a test output. An optical indication is mandatory. Beside this the meter can also have electrical test outputs. ...
The Three-phase Generator Principle

The Three-phase Generator Principle

We have a nice three phase power supply in our home, but where does it come from? And why does the waveform has a sine shape? ...

12 Replies to “Metering Blog”

  1. I have a clou meter token and am just wondering how i can silence the beeping alarm that goes off when your are low on tokens. Its kinda annoying. Ypur help will be highly appreciated.
    Regards,
    Steve

    1. Steve, try code 812 on your UIU (user interface unit) and confirm by pressing the enter-button (blue or red). If it doesn’t work, please tell us the meter model type.

    1. If the energy meter has a function for measuring reactive energy, it must have a test output (a flashing diode) indicating the reactive consumption. This test output has a meter constant, indicated in e.g. pulses per kvarh. You set measurement mode in your test plan to reactive measurement and adjust the scanning heads in front of the reactive diode. All other procedure is the same like active accuracy test. The settings for reactive power is done inside the test bench and reference standard automatically.

  2. which is the standard to be used for testing of for Reactive power in energy meter and what are the acceptable error margins?

    1. The IEC 62053-23 is applicable for static meters for reactive energy (classes 2 and 3). The allowed errors for accuracy are given in the related tables. If you have a meter with reactive class 2, the allowed error is +/-2% for all balanced loads above 0.1 Ib and power-factor 1.

  3. My CLOU (CL710K11) just shows zeros when I try to enquire balance or input new token, I think it is not communicating with the power source

    1. The possible reason could be long communicate distance or the power cable quality,plsase use another socket and try again. if still doesn’t work,pls confirm whether the UIU address is right one( enter 1593570 plus the meter number to set the UIU address).

  4. Where can I find the operational manual for clou meter, with series number CL710K11

    1. Thank you for your message. The operation manual is for the power company or utility. End users get an introduction by the power company and a reference card with the user interface short codes. The configuration for each power company is different. If you are in doubt about a function, ask your power supplier.

    2. My CL710K11 meter
      Red light is lit next to the word “WIRING” and I noticed low power in house today. Any idea what could be the problem.

      1. It indicates a poor communication between the user interface unit and the meter. One reason behind can be a very low supply voltage from the grid.