Single / Three Phase Electric Energy Meter On-site Calibrator CL3126

CL3126
CL3126

Suitable for on-site verification of single/three-phase energy meters, it complies with the on-site application requirements of power grid companies. As a high-efficiency tool specially designed for on-site power metering operations, it integrates accurate verification of single/three-phase energy meters, in-depth harmonic analysis and rapid fault line diagnosis. Adopting a mini portable design and equipped with a large high-definition display, it supports one-key operation and handheld device interconnection. Easily coping with complex on-site environments, it helps power personnel efficiently complete error detection, power quality evaluation and fault location, and serves as an intelligent tool to ensure the stable operation of power grids.

Functions

  • High Precision
    Current measurement accuracy reaches 0.02%, power/energy accuracy 0.05%. Supports dynamic energy measurement
  • Portable and Convenient
    Dual control design, touch large screen + compact button design, enhancing on-site usability
  • High Adaptability
    Backed by rigorous environmental testing, fully compliant with high and low temperature / high humidity / EMC standards, and supports optional multiple clamp meters
  • Intelligent and Efficient
    Can achieve mobile detection through ESAM encrypted connection to a unified management platform

Technical Parameters

Voltage Measurement
Voltage Measurement Range30 V … 480 V
Voltage Measurement Accuracy± 0.05%
Input Current Measurement
Direct Measurement0.05% (0.02 A … 10 A)
Clamp Meter Measurement0.2% (10% In … 120% In)
Phase Measurement Range0.00°~359.99°
Direct Measurement0.05°
Clamp Meter Measurement0.2°
Harmonic Measurement
Harmonic Measurement Range2nd … 63rd
Frequency Measurement
Frequency Measurement Range45 Hz … 65 Hz
Frequency Measurement Accuracy0.01 Hz
Power Factor Measurement
Power Factor Measurement Range– 1.0 … 0 … + 1.0
Active Power Measurement
Direct Measurement0.05% (0.02 A … 10 A)
Clamp Meter Measurement0.2% (Voltage 30 V … 480 V, 10% In … 120% In, PF ≥ 0.5)
Reactive Power Measurement
Direct Measurement0.1% (30 V … 480 V, 0.02 A … 10 A, PF ≥ 0.5)
Clamp Meter Measurement0.2% (30 V … 480 V, 10% In … 120 In, PF ≥ 0.5)
Other Indicators
Operating Power Supply/Power ConsumptionAC 85 V … 265 V, 50 Hz ± 5% / ≤ 15 VA
Harmonic Measurement Range2nd … 63rd
Operating Temperature / Relative Humidity0 ℃ … 40 ℃ / ≤ 95% RH Non-condensing

Fill the form and get reply for this product to your email-inbox.