CLOU Electronics
  • Dec 04 2020
    current 540

    Energy Saving with Little Helpers?

    I recently stumbled over some advertisements related to plug-in or paste devices which are claimed to reduce the electricity bill by an average of 10%.
  • Nov 27 2020
    uiu simulator

    User Interface Unit Simulator

    By now the UIU/CIU short-codes are not unified. We have collected and merged all recent requests.
  • Oct 30 2020
    r CL730D22L a

    How Mean is the Value?

    CLOU energy meters and test equipment is measuring the true RMS value by waveform sampling. There are other methods, but they are less accurate.
  • Oct 28 2020
    Lightning Flashes In Middle Earth

    Power Grid Stability and Renewable Energy

    With increasing percentage of renewable energy on power generation we will see more disturbances in the grid.
  • Oct 27 2020
    Waveform Sampling Basics

    Waveform Sampling for Electrical Measurements

    The interactive graphics below shows the impact on sampling rates on different waveforms. The error calculation is based on true-rms for a wave with 360 samples and for training purpose...
  • Oct 22 2020
    light

    The Over- and Under Voltage Disconnection

    The phase to neutral supply voltage is controlled by the power generation companies and utilities by using transformers with on-load tap changers. Depending on the region you can find different...
  • Oct 13 2020
    CL730D22L a

    The Over-Current Disconnect Function

    Electronic meters with build-in relays can serve for various functionalities. By IEC62052-11 Ed.2 the name for this sort of relays is Supply Control Switch (SCS).
  • Oct 12 2020
    Energy Meter Alarm

    Who pays for the Beep?

    Electronic energy meters, especially those with STS payment functions have the ability to give an alarm. Low credit is a typical example.
  • Oct 10 2020
    Energy Meter Load Limit Function

    Load Limiting for Energy Meters

    Electronic energy meters with a load switch can be programmed for a maximum load. If a consumer exceeds the limit, he will be disconnected
  • Sep 24 2020
    r CL730D22L

    Selection of Voltage Transformers

    Voltage instrument transformers (VT, sometimes also abbreviated with PT) are used on the primary side of medium- and high voltage distribution transformers.
  • Sep 22 2020
    CL730S23 TWO BUTTONS

    Selection of Current Instrument Transformers

    Transformer operated energy meters need instrument transformers to reduce high voltage- and current values to lower quantities for measurement purpose.
  • Sep 02 2020
    cat5 cable cradle wiring

    Cross-sections for electricity wiring

    Each conductor wire has a resistance. Resistance means heat development inside the wire. Technically it's a loss.