CLOU GLOBAL TECHNOLOGY provides energy management products and customized solutions for efficient energy usage, cost reduction, and sustainability compliance.
Here we are publishing answers to your questions related to our products and services.
Please do not hesitate to reach out to us if you have any questions or queries. You can use our easily accessible contact form or can leave a comment below the relevant article to get in touch with us.
Note: The calculators and animations on this website work with JavaScript-enabled Web browsers. Please make sure your Web browser is JavaScript-enabled.
Since End of 2020 we are using asynchronous scripting technologies.
Recent Articles
-
Type Tests for Energy Meters: Ensuring Accuracy and Reliability
Type Tests for Energy Meters: Learn how these rigorous evaluations ensure accuracy, reliability, and compliance in the electrical energy sector. Discover the significance of internationally recognized standards like IEC62052-11 in promoting fair competition and interoperability.
-
Harnessing the Earth's Heat: Exploring Geothermal Energy Generation
Geothermal energy, derived from the Greek words "geo" (meaning Earth) and "thermos" (meaning heat), refers to the heat energy stored beneath the Earth's surface. It is a renewable energy source harnessed by geothermal power plants to generate electricity. These power plants come in three main types: flash steam, binary cycle, and dry steam.
-
The Future of Energy: Shaping a Sustainable Tomorrow
In this article, we explore the exciting advancements and trends shaping the energy landscape of tomorrow, from renewable energy sources to smart grids and digitalization, highlighting the potential for a greener and more efficient world.
-
Energy Transition and Economic Growth: Finding the Balance
Transitioning to sustainable energy sources while ensuring economic growth is a delicate balance that requires collaboration and careful planning. This article explores the challenges, opportunities, and strategies involved in achieving this harmonious coexistence.
-
On-Shore Wind Power Generation: Advantages and Potential Drawbacks
On-shore wind power generation offers numerous advantages, including increased renewable energy generation, job creation, and reduced greenhouse gas emissions. However, it is important to address potential drawbacks such as visual impact, noise, wildlife concerns, the stroboscope effect, and the recycling challenge of wind turbine blades.
-
Decoding Meter Constant: Understanding the Expressions
In this article, we demystify the expressions used to denote meter constant, including imp/kWh, kWh/imp, and revolutions per kilowatt-hour, while highlighting the importance of calibration for accurate energy measurement. Additionally, we explore the significance of reactive energy measurement and its impact on efficient energy management.
-
Smart Meters: Addressing Concerns and Exploring Benefits
Addressing concerns surrounding smart meters is crucial to fostering understanding and informed decision-making. By dispelling misconceptions and providing accurate information, we can harness the significant advantages of improved energy management, cost efficiency, and a sustainable energy future while ensuring safety and effective implementation of this technology.
-
Unleashing the Power of Data: The Role of Energy Data Specialists in the Energy Transition
In the dynamic landscape of the energy transition, energy data specialists serve as the driving force behind unlocking the power of data. They harness advanced analytics and insightful interpretations to optimize renewable energy generation, enhance grid stability, and pave the way towards a sustainable energy future.
-
Choosing Between Post-Paid and Prepaid Meters: A Guide for Utilities
Gain valuable insights into the factors that matter most when choosing between post-paid and prepaid meters for utilities. Make informed decisions based on cost efficiency and consumer empowerment.
-
Enhancing Meter Performance and Security: The Role of Modern Meter Enclosures
Meter enclosures play a crucial role in protecting energy meters, ensuring their accurate performance, and safeguarding against tampering and unauthorized access. In this article, we explore the features and benefits of modern meter enclosures that go beyond mere protection.
-
On-Site Measurement of CT/PT Meters: Ensuring Accurate Billing
In the complex world of energy metering, disputes over accurate measurement and fair billing are all too common. On-site measurement techniques, such as absolute error measurement and differential measurement, offer transparent solutions for resolving these disputes and ensuring accurate billing practices.
-
Maintaining Measurement Accuracy Worldwide: Ensuring Reliability and Confidence
In a globalized world where precise and reliable data is paramount, maintaining similar accuracy in measurements is crucial. Explore the efforts involved in minimizing measurement uncertainty and ensuring trust and reliability in measurements worldwide.
-
Hydropower: Tapping into the Potential of Water
Discover the versatility and grid resilience of hydropower as we explore its various applications, from rivers to dams, and its role in energy storage. Join us as we uncover the power of water and its contribution to clean and sustainable energy generation.
-
The Future of Electric Vehicle Charging: Fast, Furious, and Fossil-Fuel-Free?
In this article, we delve into the exciting realm of electric vehicle (EV) charging and explore the future possibilities that lie ahead. As the world shifts towards sustainable transportation, we examine the advancements in fast charging technologies, the potential of renewable energy integration, and the quest to make EV charging truly fossil-fuel-free.
-
Transitioning from Ferraris Meters to Smart Meters: A Comprehensive Guide for Utilities
Transitioning from Ferraris meters to smart meters offers utilities numerous benefits, including improved accuracy, operational efficiency, and customer engagement. By assessing the current system, conducting a comprehensive cost-benefit analysis, and prioritizing data privacy, utilities can make informed decisions and navigate this transition seamlessly.
-
Unlocking the Benefits of Time-of-Use (TOU) Pricing with Smart Meters
Discover how smart meters enhance the benefits of Time-of-Use (TOU) pricing, providing accurate data on energy consumption patterns and empowering consumers to make informed decisions about their energy usage. Explore the potential of smart meters in optimizing TOU pricing for a more efficient and sustainable energy landscape.
-
From Virtual Replicas to Real-World Impact: The Rise of Digital Twins in the Power Sector
Digital twins in power generation and distribution enable operators to create virtual replicas of physical assets, facilitating real-time monitoring, predictive maintenance, and optimization for enhanced performance and reliability. By leveraging real-time data and advanced analytics, digital twins revolutionize asset management, paving the way for smarter, more efficient, and sustainable energy systems.
-
Harvesting Sustainable Energy: Unlocking the Power of Energy Scavenging
Energy harvesting technologies offer a promising pathway towards a sustainable energy future. By capturing ambient energy from the environment, we can power wireless sensors, IoT devices, and remote monitoring systems efficiently and autonomously.
Thank you for your unwavering commitment to excellence, and for sharing your insights on what it takes to be a world-class energy services provider. Your dedication sets a high standard for the industry. Keep up the fantastic work.
Thank you so much for your kind words and appreciation. I truly appreciate your feedback and support. It is incredibly encouraging to hear that our commitment to excellence and insights in the energy services industry have resonated with you.
Please what causes the prepared credit to ran fast?
The credit deduction is based on your consumption. If you use less electrical energy, the meter runs slower.
My CL710K11 Single Phase AMR Prepaid Meter is blinking red light at "warning" sign indicator. What does this mean?
Thanks.
If there is no other indication on the display, it means that your credit is getting low.
Thank You! So much for a great blog and best of luck for the future,
I'll be in touch.
Thank you for your interest. You can swipe down the page bottom and subscribe to our weekly newsletter.
Kindly how can I silence my meter even after dailing 812# still it will revive on its own and starts beeping its really annoying.
The beep can only switch off temporarily for just one minute.
The beep appears because there is an alarm, either low credit, or overload, or tamper.
You can silence your meter permanently after you solve the alarm.
I have a clou meter token and am just wondering how i can silence the beeping alarm that goes off when your are low on tokens. Its kinda annoying. Ypur help will be highly appreciated.
Regards,
Steve
Steve, try code 812 on your UIU (user interface unit) and confirm by pressing the enter-button (blue or red). If it doesn't work, please tell us the meter model type.
How can someone test reactive energy kvarh in a meter test bench?
If the energy meter has a function for measuring reactive energy, it must have a test output (a flashing diode) indicating the reactive consumption. This test output has a meter constant, indicated in e.g. pulses per kvarh. You set measurement mode in your test plan to reactive measurement and adjust the scanning heads in front of the reactive diode. All other procedure is the same like active accuracy test. The settings for reactive power is done inside the test bench and reference standard automatically.
which is the standard to be used for testing of for Reactive power in energy meter and what are the acceptable error margins?
The IEC 62053-23 is applicable for static meters for reactive energy (classes 2 and 3). The allowed errors for accuracy are given in the related tables. If you have a meter with reactive class 2, the allowed error is +/-2% for all balanced loads above 0.1 Ib and power-factor 1.
My CLOU (CL710K11) just shows zeros when I try to enquire balance or input new token, I think it is not communicating with the power source
The possible reason could be long communicate distance or the power cable quality,plsase use another socket and try again. if still doesn't work,pls confirm whether the UIU address is right one( enter 1593570 plus the meter number to set the UIU address).
Where can I find the operational manual for clou meter, with series number CL710K11
Thank you for your message. The operation manual is for the power company or utility. End users get an introduction by the power company and a reference card with the user interface short codes. The configuration for each power company is different. If you are in doubt about a function, ask your power supplier.
My CL710K11 meter
Red light is lit next to the word “WIRING” and I noticed low power in house today. Any idea what could be the problem.
It indicates a poor communication between the user interface unit and the meter. One reason behind can be a very low supply voltage from the grid.