Three Phase Reference Standard CL3115

Reference Standard Meter CL3115, front view
Reference Standard Meter CL3115, front view
Reference Standard Meter CL3115, rear view
Reference Standard Meter CL3115, rear view

This reference standard has accuracy class 0.02 related to apparent power
It can be used for

  • voltage measurement
  • current measurement
  • phase angle measurement
  • frequency measurement
  • harmonics analysis up to the 63th
  • power measurement, active-, reactive-, apparent
  • self consumption measurements
  • accuracy error calculations stand-alone with one pulse input socket, or together with error calculators in stationary test benches
  • register tests
Specifications

Specifications Reference Standard CL3115-HW, Mains connection

Item Values
Voltage 85 V to 265 V AC
Frequency 45 Hz to 65 Hz
Power consumption < 30 VA
Preheating time 15 minutes
Operating temperature 5 °C to 45 °C
Max. relative humidity ≤ 85%, not condensate
Surge voltage protection class C
Installation category III
Pollution degree 2
Weight approx. 13 kg
Dimensions 19” 3 units,
H x W x D: 132,5 mm x 483 mm x 405 mm

Specifications Reference Standard CL3115-HW, measurement values

Item Values
Test voltage, phase-neutral 30 V to 576 V
Voltage ranges 60 V, 120 V, 240 V, 480 V, auto range
Test current 1 mA to 120 A
Current ranges 10 mA, 20 mA, 50 mA, 0.1 A, 0.2 A, 0.5 A, 1 A, 2 A,
5 A, 10 A, 20 A, 50 A, 100 A, auto range
Frequency range, fundamental wave 40 Hz to 70 Hz
Bandwidth 4 kHz
Voltage measurement accuracy < 0.01%
Voltage measurement drift < 35 ppm/year
Current measurement accuracy < 25 mA < 0.02%
Current measurement accuracy ≥ 25 mA < 0.01%
Current measurement drift < 65 ppm/year
Power measurement accuracy P, Q, S < 0.02% (current ≥ 25 mA and λ = 1)
Power measurement drift < 100 ppm/year
Phase angle < 0.01° (current ≥ 25 mA and voltage > 30 V)
Frequency 0.005 Hz
Voltage temperature drift < 2,5 ppm/K
Current temperature drift < 5 ppm/K
Power temperature drift < 7.5 ppm/K
Errors are independent of measurement mode and when using auto range. The reference standard provides a power proportional frequency output (160 kHz nominal).

Meter Constant Table

CL3115 power constants
60 V 120 V 240 V 480 V
0.01 A 2 x 109 2 x 109 2 x 109 2 x 109
0.02 A 2 x 109 2 x 109 2 x 109 2 x 109
0.05 A 2 x 109 2 x 109 2 x 109 2 x 109
0.1 A 2 x 109 2 x 109 2 x 109 2 x 109
0.2 A 2 x 109 2 x 109 2 x 109 2 x 109
0.5 A 2 x 109 2 x 109 1.6 x 109 8 x 108
1 A 2 x 109 1.6 x 109 8 x 108 4 x 108
2 A 1.6 x 109 8 x 108 4 x 108 2 x 108
5 A 6.4 x 108 3.2 x 108 1.6 x 108 8 x 107
10 A 3.2 x 108 1.6 x 108 8 x 107 4 x 107
20 A 1.6 x 108 8 x 107 4 x 107 2 x 107
50 A 6.4 x 107 3.2 x 107 1.6 x 107 8 x 106
100 A 3.2 x 107 1.6 x 107 8 x 106 4 x 106
The table refers to the automatic settings. It's valid for 3 wire- and 4 wire measuring mode.

The output frequency for end of range in voltage/current pair with three phase connection is 160 kHz. The power pulses are on TTL/CMOS level. The burden capacity is > 20 mA.

Calculation formulas

Frequency

frequency calculation
f = frequency
UR = voltage range
IR = current range
c = reference meter constant

Constant

constant calculation

The meter constants can be set in the settings menu or selected automatic. Setting range is 1 i / kWh to 2 x 109 i / kWh.

Screenshots

The equipment can be operated manually with menu keys or via RS-485 remote control. A interface description for integration into 3rd party meter test equipment is available on request. Below are some screen-shots